Product name Manufacturer Means of Inhibiting Circuits Airsafe Plug Compatible
Sterling Elite 3&4 Sunrise Medical Ltd Switch Off & Remove Key Yes
Sterling Emerald Sunrise Medical Ltd Switch Off & Remove Key Yes
Sterling little Gem 3&4 Sunrise Medical Ltd Switch Off & Remove Key Yes
Sterling little Star Sunrise Medical Ltd Switch Off & Remove Key Yes
Sterling Melody Sunrise Medical Ltd Locate the controller cable in-line connector at the rear of the chair, depress the grey clip on the black and grey controller cable connector, to disconnect the joystick cable. Yes
Sterling Pearl Sunrise Medical Ltd Switch Off & Remove Key Yes
Sterling Ruby Sunrise Medical Ltd Disconnect the joystick control, by removal of the square shaped cable plug located at the rear of the chair Yes
Sterling Saphire 2 & LS Sunrise Medical Ltd Switch Off & Remove Key Yes
Sterling Swift Sunrise Medical Ltd Switch Off & Remove Key Yes
Storm Invacare Put device into lock mode. Whilst the controller is switched on press and hold the ON/OFF button for 4 seconds. To unlock: switch on the remote using the ON/OFF button. Press the horn button twice within the next 10 seconds. Yes
Storm 3 Invacare Put device into lock mode. Whilst the controller is switched on press and hold the ON/OFF button for 4 seconds. To unlock: switch on the remote using the ON/OFF button. Press the horn button twice within the next 10 seconds. Yes
Storm 4 Invacare Put device into lock mode. Whilst the controller is switched on press and hold the ON/OFF button for 4 seconds. To unlock: switch on the remote using the ON/OFF button. Press the horn button twice within the next 10 seconds. Yes
Storm 4 HD Invacare Put device into lock mode. Whilst the controller is switched on press and hold the ON/OFF button for 4 seconds. To unlock: switch on the remote using the ON/OFF button. Press the horn button twice within the next 10 seconds. Yes
Stream Invacare Disconnect joystick cable from connector at side of wheelchair (grey plug) and protect from short-circuit using insulation tape. Yes
Sunfire General Drive Medical Ltd Switch Off Using Push Button System & follow joystick cable down to shroud and disconnect. Yes
Sunfire Plus EC Drive Medical Ltd Whilst switched on press and hold on/off button until beep sounds. Hold joystick forward until beep sounds then hold joystick back until beep sounds. To unlock follow same procedure. Yes
Sunfire Plus GT Drive Medical Ltd Whilst switched on press and hold on/off button until beep sounds. Hold joystick forward until beep sounds then hold joystick back until beep sounds. To unlock follow same procedure. Yes
supascoota (Heavy Duty) CavendishHealthCare remove ignition key yes
supascoota (standard) CavendishHealthCare remove ignition key yes
Super 4 ForU Kymco Switch Off & Remove Key
Super 8 ForU Kymco Switch Off & Remove Key
Supersport TGA Switch Off & Remove Key Yes Battery Certificate can be supplied
Taurus Invacare Switch Off & Remove Key
TDX SP Invacare Put device into lock mode. Whilst the controller is switched on press and hold the ON/OFF button for 4 seconds. To unlock: switch on the remote using the ON/OFF button. Press the horn button twice within the next 10 seconds. Yes
Topan Invacare Put device into lock mode. Whilst the controller is switched on press and hold the ON/OFF button for 4 seconds. To unlock: switch on the remote using the ON/OFF button. Press the horn button twice within the next 10 seconds. Yes
Torino Shoprider Switch Off & Remove Key Yes
Tornado Invacare Put device into lock mode. Whilst the controller is switched on press and hold the ON/OFF button for 4 seconds. To unlock: switch on the remote using the ON/OFF button. Press the horn button twice within the next 10 seconds. Yes
Traveller Karma To lock the joystick controller press and hold on/off push button until beeps move joystick forward until beeps move joystick backwards until beeps release joystick until beeps. To unlock controller follow the same procedure. Yes
TROPHY 3W Handicare Switch Off & Remove Key
TROPHY 4W Handicare Switch Off & Remove Key
Twion Alber Passenger to provide Alber Transportation Kit (Art. No. 1591362). After switching off, Transportation Kit to be used to securely combine wheels with outer hubs facing inwards No
Typhoon Invacare Put device into lock mode. Whilst the controller is switched on press and hold the ON/OFF button for 4 seconds. To unlock: switch on the remote using the ON/OFF button. Press the horn button twice within the next 10 seconds. Yes
Typhoon 2 Invacare Put device into lock mode. Whilst the controller is switched on press and hold the ON/OFF button for 4 seconds. To unlock: switch on the remote using the ON/OFF button. Press the horn button twice within the next 10 seconds. Yes
UL480 Electric Mobility Switch Off & Remove Key Yes
UL765 Electric Mobility The product can be carried intact or may be collapsed if necessary for transport. If intact disconnect the electrical cable connector between the joystick and the battery case (nearest the battery case). If collapsed remove the plastic battery case protect the three brass terminal plates on rear from short-circuit (e.g. by using insulation tape) and pack within a strong rigid packaging. Yes
Valencia Shoprider Switch Off & Remove Key Yes
Vantage Electric Mobility Switch Off & Remove Key Yes
Vantage x Electric Mobility Switch Off & Remove Key Yes
Venice Shoprider Remove front cover which is secured with velcro and separate Anderson connector. Yes
Ventura Electric Mobility Switch Off & Remove Key Yes
Veo Electric Mobility Switch Off & Remove Key Yes
Veox Electric Mobility Switch Off & Remove Key Yes
Verb41 Patterson Medical Separate the connectors between the two batteries and protect terminals with insulation tape. Yes
Verb46 Patterson Medical Separate the connectors between the two batteries and protect terminals with insulation tape. Yes
Vienna Shoprider Follow lead from the rear of the joystick. Unplug from frame connector by depressing lock tab and carefully pulling away. DO NOT pull by the cable to unplug. Yes
Viper Patterson Medical There are four different controllers that may be fitted. For the controller badged 'DX2' hold the power button until the padlock symbol appears (to unlock turn on controller and press horn twice within 10 seconds). For other controllers either unplug the cable from the controller housing or follow the cable from the controller housing and separate the inline connector. Yes
Viper Team Hybrid Ltd Yes disconnect batter plug from motor No
Viper FWD Patterson Medical There are four different controllers that may be fitted. For the controller badged 'DX2' hold the power button until the padlock symbol appears (to unlock turn on controller and press horn twice within 10 seconds). For other controllers either unplug the cable from the controller housing or follow the cable from the controller housing and separate the inline connector. Yes
Viper Plus Patterson Medical There are four different controllers that may be fitted. For the controller badged 'DX2' hold the power button until the padlock symbol appears (to unlock turn on controller and press horn twice within 10 seconds). For other controllers either unplug the cable from the controller housing or follow the cable from the controller housing and separate the inline connector. Yes
Vision Electric Mobility Switch Off & Remove Key Yes